Program
/ Run Sw.
Operational Programming
Test Button
Overload Adjustment
Overload LED
Closing Speed Adjustment
Control
Input Functions:
Activation
Signal (Act'n 1)
Delayed Activation Signal (Act'n 2)
Closing Door Safety (Safety 1)
Opening Door Safety (Safety 2)
Hold Open
Control
Features:
Digital
Input Programming
Wide Operational Parameter Setting
System Error Diagnosis
Cycle Counter
Reversible Circuits (NC/NO)
24V Power output
Motor
Features:
90kg~150kg
Load capacity
Robust motor gear box
Near silent acceleration and braking
Smooth and controlled operation
Incorporating
unique clutch gear
|
Program
/ Run Sw. - In normal operation, switch will be
set to 'Run'. For programming requirements, it is necessary
to move switch to 'Program'.
Operation
Programming - Using in combination the 2 button
programming input facility, with the Digital LED Display
(LED '1' & '2'). Operational setting can be adjusted
with ease.
Button
No.1 - Pass - Provides stepped access to parameters,
functions, applications and operational history.
Button No.2 - Set - Provides stepped value adjustment
of selected operational features as well as cycle counter.
All
operators are supported with a setting code table which
allows installers to 'fine tune' each installation.
The setting code table details each function and available
value. Default values can be reset by depressing button
1 & 2 together for 5 secs.
Digital
LED display also gives indication of power to the control
system is present.
Test
Button - Activation button is provided for testing
and installation purposes.
Overload
Adjustment- Overload is the torque adjustment setting
for the amount of pressure with which the door pushes
against an obstruction, before cutting off for safety.
Overload can be adjusted by pot.
Overload
LED - Indication of Overload is shown by this helpful
LED. Allowing a visual confirmation of correct installation.
Closing
Speed Adjustment - Closing speed is powered by the
spring and regulated by motor resistance. Speed can
be adjusted by pot.
|